User access control
What is user access control?
By default, anyone with access to the AOI can use the software and change any of its settings.
User access control lets you create individual accounts and require a username and password every time the software starts. Each account has a role that determines what its user is allowed to do, so you can let an operator run inspections while keeping the configuration of the machine protected.
The two roles
Every account has one of these two built-in roles, or a custom role created by an administrator:
| admin | operator | |
|---|---|---|
| General, Workflow and Report options | Yes | Yes |
| Date/time, Path and Share options | Yes | No |
| Users, Sequences, Machine and Debug | Yes | No |
| Take a REFERENCE image | Yes | Only if operator mode is disabled |
| Manage users | Yes | No |
| Calibrate the platform | Yes | No |
| Set the settings password | Yes | No |
| Generate a backup | Yes | No |
The operator role and operator mode are not the same thing
The operator role described here limits which tabs of the settings menu the user can open.
Operator mode, in Settings → Workflow, simplifies the interface and blocks the capture of REFERENCE images. It applies to whoever is using the machine, regardless of their role.
They can be used together: an operator account with operator mode enabled gets both the simplified interface and the restricted settings.
Custom roles and permissions
Beyond the built-in admin and operator roles described above, administrators can create additional roles from the Roles list at the bottom of the Users tab of the settings menu.

Press New role, give it a name and press Create.

Select the new role in the list and press Edit permissions to choose exactly what it grants. Permissions are grouped into categories such as Reference, Inspection and Maintenance — for example creating or deleting a reference variant, running inspections, or calibrating the platform — and each category has its own Select all / Deselect all shortcut.

The Permissions granted column shows how many of the available permissions each role currently has, e.g. 23/35.
A custom role then appears alongside admin and operator in the Role field when adding or editing a user.

A new role starts with only the permissions needed to run inspections, classify detections and export reports. Everything else has to be granted from Edit permissions.
When a software update adds a new permission, the operator role receives it automatically. Custom roles do not: an administrator has to grant it to them explicitly. Recent updates added, among others:
| Permission | Allows |
|---|---|
| Classify detected faults | Reporting detections as actual errors or false positives. Without it, a Permission denied message is shown. Marking a detection as seen is always allowed. |
| Max. variants per Reference | Changing Max. variants per Reference. |
| Reference statistics and heatmap option | Changing Show statistics and error heatmap per Reference. |
| Analysis preference | Changing Analysis preference. |
| Edit Reference options | Changing the mandatory review levels of a REFERENCE in its Reference options. |
Note
The built-in admin and operator roles cannot be renamed, have their permissions edited, or be deleted.
Mandatory review per role
With user access control enabled, the mandatory review levels are set for each role instead of globally: the Roles list has a column for each level (Mandatory review, Mandatory report and Final report), and the Edit permissions window of the role has a checkbox for each one. Changing them requires access to the Users tab.
The global options in Settings → Workflow are grayed out while user access control is enabled, and keep their value for when it is disabled again.
- The admin role is never affected by these settings; only a REFERENCE that requires a level applies to it.
- New roles start with the three levels disabled.
- The first time the roles are loaded after updating to 7.11, each existing role takes the value that the global Mandatory errors review option had, so no existing obligation is lost. The report and final report levels start disabled for every existing role.
Setting it up
1. Open the Users tab
Open the settings menu and go to the Users tab. On a machine that has never been configured, the list is empty and the access control is disabled.

2. Create an administrator first
Before anything else you need an admin account. If you try to enable the access control without one, the software refuses:

Press Add user, fill in the username, select the admin role, leave Active user checked and type the password twice.

Press Save. The new account appears in the list, with the date it was created.

Important
Store the administrator password somewhere safe. Once the access control is enabled, this is the account that lets you back into the settings menu.
3. Enable the access control
With an active admin account in the list, enable Enable user access control.

4. Add the rest of the users
Add an account for each person who will use the machine, giving them the operator role unless they need to change the configuration.

The list shows every account with its role, whether it is active, and the dates on which it was created and last modified.

Press OK to save and close the settings menu.
Logging in
From the next start of the software, the User access required dialog asks for the credentials of one of the accounts you created.

The software then opens with the permissions of that account.
The logged-in user is shown in the activity log.
To close the session and let a different user log in, use the logout button of the platform status area. It asks for confirmation and then clears the workspace (loaded REFERENCE and inspection results), so the next user starts fresh.
Managing the accounts
Select an account in the list to work with it:
- Edit user — changes the role, the password or the active state of the selected account.
- Delete user — permanently deletes it. A confirmation is requested.
Deactivate instead of deleting
To stop someone from using the machine without losing the record of their account, edit the user and clear the Active user checkbox. The account stays in the list but can no longer log in.
Note
There must always be at least one active admin account. Keep this in mind before deactivating or deleting an administrator.
Inactivity lock
With user access control enabled, the User access control panel of the Users tab also offers an optional inactivity lock: enable Lock after inactivity and set the number of minutes of keyboard and mouse inactivity after which the application should lock itself.

Once that time elapses, the User access required dialog appears again, the same as at startup, without closing the current REFERENCE or losing the results of the inspection in progress. Any active user can unlock it, not only the one who was logged in. The lock never triggers while an inspection is in progress or while Demo / Loop mode is running.
Note
This option only appears once user access control is enabled, since locking the application requires an account to unlock it with.