The software does not start/respond

Remove the setup.json file located in the APP folder and then launch the application again.

Warning

All configurations, such as the mosaic menu, will be lost. The REFERENCES can be loaded later by using the Load REFERENCE button. They can be reloaded later. ONLINE users must log in with their AgnosPCB account after deleting the setup.json file.

When trying to launch the application, a message appears saying that the file does not have permissions to launch.

Open a terminal window (You can use the keyboard shortcut CTRL + ALT + T) and type the following:

chmod +x APP/Agnospcb.sh
chmod +x APP/Agnospcb.bin
The camera does not complete the initialization procedure and is colliding with the frame

You can adjust the return-to-origin parameters by editing the machine.json file, located in the APP folder. There are three parameters that adjust the axis endstops:

{
...
"xhome":60,
"yhome":50,
"zhome":30,
...
}

Modify the parameters of the affected axis by increasing the value if the axis does not stop when it reaches the end. Decrease the value if the axis does not reach the end.

I am getting “time-out” errors when inspecting my circuits. How do I solve it?

This could be due to a slow internet connection. Avoid using a Wi-Fi connection to ensure good speed. It could also be that a firewall on your local network is blocking the connection. Try accessing the following web address from the AOI to check if a firewall is blocking the connection.

The sensitivity returns to the default value after performing an inspection.

There is a parameter in the setup.json file called "remember_sensitivity". Modify the file and set this value to 1 to hold the sensitivity between inspections.